When chrono-proportional mode is set, the thermostat introduces a fixed cycle rate on the system and then determines the duration of the On and Off periods within each cycle in proportion to load. Both features dynamically adjust according to performance accuracy each day to ensure most acurate control and remove the need for manual setting and adjustment. I have the same thermostat (DANFOSS TP5000Si) and although I've looked at the manuals available online I can't find out what I want to know. This product should only be installed by a qualified electrician or competent heating installer and should be in accordance with the current edition of the IEEE wiring regulations.

Danfoss Programmable Room Thermostat TP5000 Si

Instructions on how to access this feature are available from our customer support desk. Please note these are only issued to boni-fide heating installers. If you've got a Marcus easy-access savings account or cash ISA, you can easily boost your interest rate to 4.75% – here's how.

Danfoss Programmable Room Thermostat TP5000 Si

This allows the lower limit of the thermostat setting range to be electronically limited. Press + until Option 31 is displayed, use V and Λ to select required setting. Is this possible with this thermostat? I can't find out how to do this online. I can see how to put it in 'summer mode' but then I can't turn it on again without that reactivating the annoying coming off programmed settings. At the moment the heating comes on and turns itself off at certain times throughout the day inherited from the previous tenant. Sometimes it comes on when I am out, other times I'll have the heating on in the afternoon or evening and suddenly realise I am cold and that it has turned itself off. Superdrug adds new 'VIP Rewards' offers to its existing loyalty scheme – here's what you need to know The control algorithm used to determine the on/off periods uses a proportional + integral (PI) routine to eliminate offset normally associated with on/off or simple proportional control.

danfoss tp5000rf /tp5.2rf there seems to be no reset I have a danfoss tp5000rf /tp5.2rf there seems to be no reset

I want the heating to be off unless I specifically choose to turn it on or off manually. And when I have put it on I want it to stay on until I turn it off. All I can find out to do online is to change the times the heating comes on and off. The thing is, I have a disability so sometimes I''m in bed all day or whatever and just want it off and I can't afford to have the heating working according to these settings.

MSE News

This allows the upper limit of the thermostat setting range to be electronically limited. Press + until Option 30 is displayed, use V and Λ to select required setting. For TPOne we have redesigned the heating startup options. Standard startup is default giving instant heat at the scheduled time. New dynamic Delayed and Optimised start features are also selectable. Delayed start will pause the heating startup at the scheduled time dependant on the difference between ambient and required temperature which will decrease energy usage. Optimised start will monitor the difference between ambient and required temperature and will calculate the best time to start heating to hit setpoint at the scheduled time. If you're a regular Superdrug shopper, you can now earn more freebies and discounts under its Health & Beautycard loyalty scheme, as the retailer has launched new 'VIP Rewards' as part of it.